4G-LTE RS485 Modbus Gateway with 5 Analog & 5 Digital Inputs

HashStudioz introduced the 4G-LTE RS485 Modbus Gateway, a compact solution designed for efficient data acquisition and transmission. It offers comprehensive monitoring capabilities with 5 Analog Inputs and 5 Digital Inputs. Compatible with the Modbus RTU Protocol via RS485, it ensures seamless communication with various devices. Users can customize settings for data speeds and parity, optimizing integration flexibility. Additionally, with support for REST API and MQTT transmissions, it provides versatile connectivity options for diverse network environments. Its compact design, rugged durability, and personalised support make it ideal for industrial applications.


Key Features

  • 4G-LTE Modbus Gateway: Industrial data transmission solution.
  • Analog Input: 5 channels, 4-20mA support, 12-bit ADC.
  • Digital Input: 5 channels, 24VDC support, isolated.
  • Communication: RS485, Modbus RTU, customizable.
  • Connectivity: REST API, MQTT support.
  • Security: Encryption for data protection.
  • Installation: Plug and play.
  • Rugged Design: Metal enclosure, wide operating range.
  • Efficiency: Low power consumption.

Application

  • Industrial Monitoring: Analog inputs for parameters, digital for equipment status. Connects to PLC/SCADA via Modbus RTU.
  • Environmental Monitoring: Collects data (air quality, etc.) in remote areas, transmits to cloud via REST API/MQTT.
  • Smart Agriculture: Integrates with soil sensors, monitors conditions, optimizes irrigation via MQTT.
  • Energy Management: Monitors energy consumption, integrates with meters, optimizes usage via REST API.
  • Remote Equipment Control: Controls pumps, generators remotely via Modbus RTU/RS485, reduces downtime with MQTT

Specifications

Connectivity
Supported RS485
Communication Interface
2 Wire Type
Baud Rate
9600 – 115200 Kbps (SW selectable)
Modbus Simplex
@1200bps - 115200bps
Watchdog Timer
System (5 Sec) and Communication
Protocol Supported
Modbus RTU
TCP/IP Protocol
TCP /IP,UDP
Encryption
WEP64/WEP128/TKIP/AES
Data format
JSON
Input Power
Unregulated 9 – 24 VDC
Power Consumption
Less than 1 W @ 12 VDC
Connector
3mm pitch screw terminal blocks
Enclosure
Metal Enclosure
Installation Type
Plug and Play
Communication Interface
2 Wire Type
Modbus Wire
Twisted pair Shielded Cable < 1200mtr
Antenna
External
Indication
Power, Sim, Communication & Publish
LED Indicator
Power, Net Act, Sim Status, LTE Status, Modbus Communication
Operating Temperature
-6 – 60 °C
Storage Temperature
-10 to 70°C
Operating Humidity
5 – 95% RH (non-condensing)

Analog Input

Channel
5
Contact Rating
4-20mA with 12 bit SAR ADC (Transient Protected)(80 dB CMRR)
Standard
Single ended 12 bit ADC

Digital Input

Channel
5
Contact Rating
24 VDC Sink/source (isolated) Up to 5000 VRMS for 1 minute
Standard
Digital Isolator type IEC 60950

FAQs

Q1. What is the 4G-LTE RS485 Modbus Gateway introduced by HashStudioz?
  • A1. The 4G-LTE RS485 Modbus Gateway is a compact solution designed for efficient data acquisition and transmission. It offers comprehensive monitoring capabilities with 5 Analog Inputs and 5 Digital Inputs.
Q2. What communication protocols are supported by the Modbus Gateway?
  • A2. The Modbus Gateway supports the Modbus RTU Protocol via RS485 for seamless communication with various devices. It also supports TCP/IP Protocol for versatile connectivity options.
Q3. How are the operating conditions of the Modbus Gateway defined?
  • A3. The Modbus Gateway operates within an operating temperature range of -6 to 60°C and can be stored within a temperature range of -10 to 70°C. It operates in humidity conditions ranging from 5 to 95% RH (non-condensing).
Q4. What communication protocols are supported by the Modbus Gateway?
  • A4. The Modbus Gateway supports Modbus RTU protocol via RS485, as well as TCP/IP protocol with TCP and UDP options.

FAQs

Q1. What is the 4G-LTE RS485 Modbus Gateway introduced by HashStudioz?
  • A1: The 4G-LTE RS485 Modbus Gateway is a compact solution designed for efficient data acquisition and transmission. It offers comprehensive monitoring capabilities with 5 Analog Inputs and 5 Digital Inputs.
Q2. What communication protocols are supported by the Modbus Gateway
  • A2: The Modbus Gateway supports the Modbus RTU Protocol via RS485 for seamless communication with various devices. It also supports TCP/IP Protocol for versatile connectivity options.
Q3. How are the operating conditions of the Modbus Gateway defined?
  • A3: The Modbus Gateway operates within an operating temperature range of -6 to 60°C and can be stored within a temperature range of -10 to 70°C. It operates in humidity conditions ranging from 5 to 95% RH (non-condensing).
Q4. What communication protocols are supported by the Modbus Gateway?
  • A4: The Modbus Gateway supports Modbus RTU protocol via RS485, as well as TCP/IP protocol with TCP and UDP options.